Caudalímetro de paletas

Category:

2536 Rotor-X Paddlewheel Flow Sensors

Caudalímetros
Descripción

Simple to install with time-honored reliable performance, Model 2536 Rotor-X Paddlewheel Flow Sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. The Model 2536 has a process-ready open collector signal and has a wide dynamic flow range of 0.1 to 6 m/s (0.3 to 20 ft/s). The sensor measures liquid flow rates in full pipes and can be used in low pressure systems.

The Model 2536 sensors are offered in a variety of materials for a wide range of pipe sizes and insertion configurations. The many material choices including PP, PVDF, and Tefzel make this model highly versatile and chemically compatible with many liquid process solutions. Sensors can be installed in DN15 to DN900 (0.5 to 36 in.) pipes using Signet’s comprehensive line of custom fittings. These custom fittings, which include tees, saddles, and weldolets, seat the sensor to the proper insertion depth into the process flow. The sensors are also offered in configurations for wet-tap installation requirements.

Características

-Flow rate range 0.1 to 6 m/s (0.3 to 20 ft/s)
-Wide Turndown Ratio of 66:1
-Open-collector output
-Simple, economical design
-Highly repeatable output
-Installs into pipe sizes DN15 to DN900 (0.5 to 36 in.)
-High resolution and noise immunity
-7.6m (25 ft.) of cable for standard and Wet-Tap sensors
-Chemically resistant materials
-Easy to replace rotor
-CE Approved
-Pure Water Production
-Filtration systems
-Chemical Production
-Liquid Delivery Systems
-Pump Protection
-Scrubber Systems
-Water Monitoring
-Not suitable for gases

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

515 Rotor-X Paddlewheel Flow Sensors

Caudalímetros
Descripción

Simple to install with time-honored reliable performance, Model 515 Rotor-X paddlewheel flow sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. The output signal of the Model 515 is a sinusoidal frequency capable of driving a self-powered flowmeter (Model 5090). The wide dynamic flow range of 0.3 to 6m/s (1 to 20 ft/s) allows the sensor to measure liquid flow rates in full pipes and can be used in low pressure systems.

The Model 515 sensors are offered in a variety of materials for a wide range of pipe sizes and insertion configurations. The many material choices include PP, PVDF, and Tefzel make this model highly versatile and chemically compatible to many liquid process solutions. Sensors can be installed in up to DN900 (36 in.) pipes using Signet’s comprehensive line of custom fittings. These custom fittings, which include tees, saddles, and weldolets, set the sensor to the proper insertion depth into the process flow. The sensors are also offered in configurations for wet-tap and intrinsically safe installation requirements.

Características

-Flow rate range 0.3 to 6 m/s (1 to 20 ft/s)
-Wide Turndown Ratio of 20:1
-Highly repeatable output
-Simple, economical design
-Installs into pipe sizes DN15 to DN900 (0.5 to 36 in.)
-Self-powered
-7.6m (25 ft.) cable for Standard and Wet-Tap sensors
-Chemically resistant materials
-Easy to replace rotor
-FM and CE Approved
-Pure Water Production
-Filtration systems
-Chemical Production
-Liquid Delivery Systems
-Pump Protection
-Scrubber Systems
-Water Monitoring
-Not suitable for gases

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

2537 Rotor-X Paddlewheel Flowmeter

Caudalímetros
Descripción

The NEW Signet 2537 Flow Sensor is the next generation in fluid measurement technology from the inventor of the original paddlewheel flowmeter. This new sensor is an enhancement on what’s already an industry standard. It has the added functionality of various output options including flow switch, pulse divider, digital (S3L) or 4 to 20mA. Additionally, it offers low flow, low power and high resolution options and can be configured on-site directly through the built-in user interface. Installation is simple because the Signet 2537 utilizes the same fittings as the popular Signet 515 and 2536 Paddlewheel Sensors, and fits into pipe sizes ranging from DN15 to DN200 (0.5 to 8 inches). Available in a variety of wetted materials, such as Polypropylene and PVDF, it is ideal for a variety of applications including chemical processing, water and wastewater monitoring and scrubber control.

Características

-Digital (S3L) and 4 to 20mA outputs
-Available with Flow Switch and Pulse Divider output
-Allows up to six connections to Signet 8900 Controller
-Low flow capabilities down to 0.1m/s (0.3 ft/s)
-Available with Polypropylene and PVDF wetted materials
-Installs into pipe sizes DN 15 to DN 200 (0.5 to 8 in.)
-Built-in user interface for on-site configuration
-Low power and high resolution options
-Process Flow Monitoring
-Pump Protection
-Pure Water Production
-Filtration Systems
-Chemical Production
-Reverse Osmosis
-Demineralization/Regeneration
-Fume Scrubbers
-Cooling Towers

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

525 Metalex Flow Sensor

Caudalímetros
Descripción

The Signet 525 Metalex Flow Sensor offers the added strength of an all stainless steel construction with insertion paddlewheel technology. The result is a highly reliable sensor resistant to extreme pressures and temperatures. The Tungsten Carbide shaft with Fluoroloy B® bearing provide an increased length between maintenance. A comprehensive fitting program allows installation in steel lines with the mini-block for small diameters, and either the mini-tap or saddle for pipes up to DN300 (12 in.). The self-generating signal output allows use with battery operated flow monitor (8150).

Características

-Withstands high pressures and temperatures
-FM approved
-0.5 to 12″ pipe range
-Simple Installation
-Tungsten Carbide or Stainless Steel rotorshaft
-Boiler Feedwater monitoring
-HVAC systems
-Chemical transport
-Heat exchangers
-Reverse Osmosis
-Boiler Condensate

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

2507 Mini Flow Sensor

Caudalímetros
Descripción

The Signet 2507 Mini Flow Sensor contains a free-running rotor that is driven by the fluid flow. Within the given measurement range, the rotational speed of the rotor is proportional to the fluid flow rate. Permanent magnets built into the rotor actuate an electronic switch in the top of the sensor generating a square-wave output signal proportional to flow rate. Both opaque and transparent fluids can be measured from 0.2 to 20.0 centistokes.

Características

-Compact Assembly
-Simple Installation
-1/4″ Threaded Connection
-Detachable Signal Connector
-PVDF Construction
-Four Flow Ranges
-Fluid Dispensing
-Laboratory and Clinical Wet Benches
-Chemical Dosing
-Batch Processes

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

2000 MicroFlow Sensor

Caudalímetros
Descripción

The Signet 2000 MicroFlow Sensor is constructed from PPS which provides high material strength. The 2000 offers two flow ranges starting at 0.03 or 0.7 gpm, for clean process liquids, regardless of fluid color or opacity. This sensor can be connected to flexible tubing or rigid pipe, and uses standard hardware for mounting. Only one moving part and a low pressure drop across the sensor reduces operating costs and maintenance requirements.

Características

-Two flow ranges available
-0.11 to 2.6 lpm (0.03 to 0.7 gpm)
-1.13 to 12.11 lpm (0.3 to 3.2 gpm)
-Simple Mounting
-1/4 in. NPT or ISO threads for simple pipe or tubing connection
-Measures clear and dark liquids
-Coolant Flow
-Dosing
-Batch dispensing
-Not recommended for strong oxidizers

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

8550 ProcessPro™ Flow Transmitter

Caudalímetros
Descripción

The Signet 8550 Flow Transmitter is an advanced solution that converts the signal from all Signet flow sensors into a 4 to 20 mA signal for long distance transmission, and offers the unique feature of dual input and output capability. Configuration flexibility is maximized with two optional relays for process control, two packaging options for integral/pipe mount or panel installation, and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability, signal stability, and simple user setup and operation.

Características

-Permanent & resettable totalizers
-Scaleable outputs
-Relay options
-Mounting versatility
-Simulate function
-2 x 16 character dot matrix LCD
-Chemical resistant enclosure and self-healing window
-Large pushbuttons
-Clearly marked terminal labels
-Flow control and monitoring
-Filtration or softener regeneration
-Effluent totalization
-Pump protection
-Feed pump pulsing
-Ratio control
-Water distribution
-Leak detection

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

8150 Battery Powered Flow Totalizer

Caudalímetros
Descripción

The Signet 8150 Battery Operated Flow Totalizer is compatible with the Signet 515, 525 and 2517 flow sensors, and will provide years of dependable operation. The large digital display indicates flow rate and totalized flow volume simultaneously. One of the three totalizers is resettable from the front panel or a remote location, while the second resettable totalizer can only be reset by entering a user-selectable security code. Meanwhile, the third is a permanent non-resettable totalizer. Our intuitive software design and four-button keypad provide for simple operation while setting screen displays and programming the system. Calibration can be easily performed by entering the Auto-Cal feature and entering a value to match an external reference. Screen displays can be modified to suit the user’s needs; along with the flow rate, any of the three totalizers can be selected as the displayed totalizer. Customers can quickly scroll through the totalizers simply by pressing any key on the keypad. A display averaging feature is included for applications where the flow in the pipe fluctuates. For applications where flow stops and starts due to production needs, a no-flow indicator will display the hours of non-flow.

Características

-Three totalizers
-Long-lasting lithium batteries
-Mounting versatility
-No-flow indicator
-Large digital display with averaging
-Simple push-button operation
-User selectable access code prevents unwanted changes
-Auto-calibration
-Wastewater Flow Accumulation
-Water Treatment Systems
-Remote or Mobile Treatment/Distribution Systems
-Irrigation Systems
-Filtration Systems
-Commercial Pools & Spas
-Groundwater Remediation
-RO Concentrate
-Process Flow Monitoring
-UPW Distribution
-Demineralizer Regeneration
-Process Cooling Water
-Neutralization Systems

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

5075 Totalizing ProPoint™ Flow Monitor

Caudalímetros
Descripción

The Signet 5075 Totalizing Flow Monitor displays flow rate on a highly visible analog dial, and uses a backlit LCD for displaying totalized flow volumes. One of the two totalizers is resettable from the front panel, and can also be reset from a remote location up to 30 m (100 ft.). The other totalizer is non-resettable and is commonly used to tally consumption, or to permanently record industrial effluent volumes. The monitors require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. Our intuitive software design and four-button keypad arrangement provide for simple operation, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Back Cover Kit.

Características

-Analog and Digital display
-Two 8-digit Totalizers: one permanent, the other resettable
-Tamper proof security code
-Non-volatile memory
-Intuitive Software Design
-Simple push-button operation
-Programmable pulse outputs
-Versatile low voltage power requirement
-1/4 DIN, NEMA 4X/IP65 enclosure
-Quality Standards: UL, CE
-Waste Water Flow Accumulation
-Water Treatment Systems
-Filtration Systems
-Feed Pump Pulsing
-Fertigation
-Irrigation
-Commercial Pools & Spas
-Groundwater Remediation
-HVAC
-Process Flow Monitoring
-UPW Distribution
-Demineralizer Regeneration
-Process Cooling Water
-Neutralization Systems

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.

 

5600 ProPoint™ Batch Controller

Caudalímetros
Descripción

The Signet 5600 Batch Controller is an extremely refined instrument that combines complex control capability with operational simplicity. Select either Simple or Advanced mode to limit feature options to suit your specific batch requirements, and make changes to batch volume quickly and easily. Two relays and one analog output provide the means to increase batch precision while dramatically reducing the possibility of water hammer in a system. Batch progress is displayed on the analog dial, while the backlit LCD is used for calibration, set-up, and to show totalized flow volumes. The controllers require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. The intuitive software design and four-button keypad arrangement is user friendly, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Rear Cover Kit.

Características

-Simple push-button operation
-Intuitive Software Design
-Easy Batch Volume Entry
-Simple and Advanced operating modes
-Remote Start, Stop & Resume
-Auto-calibration
-Two Stage Shutdown Control
-Manual or Automatic Overrun Compensation
-Estimates Time to Batch Completion
-Overrun Alarm
-Missing Signal Alarm
-Advanced Valve Control
-End-of-batch Trigger
-Count-up or Count-down to Batch Completion
-Dual Totalizers
-Tamper-proof Security Code
-Non-volatile memory
-Versatile low voltage power requirement
-1/4 DIN, NEMA 4X/IP65 enclosure
-Hard-coated, High Impact & UV resistant polycarbonate front face
-Batch Processes
-Filter Backwash Initiation
-Chemical Addition
-Canning & Bottling

Aplicaciones

The requirements placed on fluid measurement systems are as diverse as the applications in which they are implemented. Here you will find useful information that will answer your particular measurement questions and provide you with examples of similar applications.